Your position : Plating Equipment : Highly Flexible Copper Connectors : Braided Cables - Insulated and Not Insulated

  
Highly Flexible Copper Connectors 
Solderless Pressed Design

 
Drawings
Technical data

These cables are extra flexible. They are made of highly flexible braided strands of 0,07 / 0,10 mm Ø bare or tin coated wire. The ends of the cable have seamless contact areas which have been pressed on under extreme pressure (not soldered). By using this production method material of same analysis and same conductivity (E-Cu tubing and stranded wire) is being connected without using foreign materials like tin or welding additions. This creates a flexible component with very low resistance. Upon request, the current cables can also be insulated with PVC/silicone or another insulating material. For use in galvanising equipment, we also provide liquid resistant versions. We produce customer specific versions to plan or drawing on short notice and inexpensively. The values shown on the next page refer to individual cables and are independent standard values. When cables are run parallel to one-another then the specific current load is similar to DIN 43671. When using insulated connections, the current load capability is decreased by approx. 15 - 20 % of the value in the tables.

In galvanising equipment, these cables perform extremely well for connecting contacts, rectifiers or transformers to the current supply system as well as for compensating for tank movement. We also provide assembled round cables for rectifiers that must have a flexible connection.

Copper Connectors non-insulated Copper Connectors with Standard Insulation

Copper Connectors liquid-resistant insulated

Round Connectors with and without Insulation


Highly Flexible Copper Connectors 
Solderless Pressed Design

 

Part No.

Type

Cross section
mm²

Dimensions mm approx.

Load A

Standard drilling

B

L1

S

DC

AC

02930

I

25

20

20

3,5

150

140

Typ I

02931

50

5

250

240

02932

 

75

 

 

7

350

340

02933

100

 

 

8

400

380

02934

I

25

25

25

3,5

150

140

02935

 

50 

 

 

4,5

300

280

02936

 

75

 

 

6

350

340

02937

 

100

 

 

7

450

420

02938

 

125

 

 

8,5

500

470

02939

I

50

30

30

4

300

290

02940

 

75

 

 

5

400

390

02941

 

100

 

 

6

450

440

02942

 

150

 

 

8,5

550

540

02943

 

200

 

 

11,5

650

640

02944

 

300

 

 

15,5

800

790

02945

I

100

40

40

7,3

500

480

02946

 

150

 

 

7,6

600

590

02947

 

200

 

 

9,5

700

680

02948

 

250

 

 

11

800

780

02949

 

300

 

 

13

900

850

02950

 

400

 

 

15,5

1000

980

02951

II

140

50

50

6

650

630

Typ II

02952

 

210

 

 

8

800

780

02953

 

280

 

 

10

950

900

02954

 

420

 

 

14

1050

1000

02955

 

560

 

 

16

1350

1200

02956

II

140

60

60

6,5

700

680

02957

  

210

 

 

8

900

850

02958

350

 

 

11

1150

1100

02959

  

490

 

 

13

1350

1300

02960

  

560

 

 

15

1400

1350

02961

III

340

80

80

9,5

1200

1100

Typ III

02962

  

500

 

 

11,5

1500

1400

02963

  

670

 

 

14,5

1700

1600

02964

  

840

 

 

16

1900

1800

02965

  

1000

 

 

19,5

2100

1950

02966

III

500

100

100

11

1600

1500

02967

  

670

 

 

12,5

1850

1790

02968

840

 

 

14,5

2100

2000

02969

  

1000

 

 

17,5

2250

2150

02970

1200

 

 

19

2450

2350

02971

1500

 

 

23,5

2700

2550

02972

III

600

120

120

12

1900

1750

02973

  

1000

 

 

16

2650

2500

02974

  

1500

 

 

21

3400

3200

02975

  

2000

 

 

26

3950

3800

02976

  

3000

 

 

36

4800

4550

02977

  

4500

 

 

51

5400

5400

Note: The defined load capacities are independent standard values for non-insulated versions. The reduction factor for insulated versions depending on the application is between 15-20 %. The standard version is non-insulated. Standard insulation is PVC. If desired we can provide materials such as silicone fibre-glass shrinking plastic tubing etc. If required please indicate: Part No. Overall length; if drill holes are required then please include the type or provide a schematic; if insulation is desired then please indicate specifications. For insulation other than PVC please indicate which type and if they should be impermeable to liquid then please indicate this as well.