Highly Flexible Copper Connectors
Solderless Pressed Design
Drawings
Technical data
These cables are extra flexible. They are made
of highly flexible braided strands of 0,07 / 0,10 mm Ø bare or
tin coated wire. The ends of the cable have seamless contact areas
which have been pressed on under extreme pressure (not soldered).
By using this production method material of same analysis and same
conductivity (E-Cu tubing and stranded wire) is being connected
without using foreign materials like tin or welding additions.
This creates a flexible component with very low resistance. Upon
request, the current cables can also be insulated with
PVC/silicone or another insulating material. For use in
galvanising equipment, we also provide liquid resistant versions.
We produce customer specific versions to plan or drawing on short
notice and inexpensively. The values shown on the next page refer
to individual cables and are independent standard values. When
cables are run parallel to one-another then the specific current
load is similar to DIN 43671. When using insulated connections,
the current load capability is decreased by approx. 15 - 20 % of
the value in the tables.
In galvanising equipment, these cables perform
extremely well for connecting contacts, rectifiers or transformers
to the current supply system as well as for compensating for tank
movement. We also provide assembled round cables for rectifiers
that must have a flexible connection.
|
|
|
Copper Connectors non-insulated
|
Copper Connectors with Standard Insulation
|
|
|
Copper Connectors liquid-resistant insulated
|
Round Connectors with and without Insulation
|
Highly Flexible Copper Connectors
Solderless Pressed Design

Part No. |
Type |
Cross section
mm² |
Dimensions mm approx. |
Load A |
Standard drilling |
B |
L1 |
S |
DC |
AC |
02930 |
I |
25 |
20 |
20 |
3,5 |
150 |
140 |
Typ I

|
02931 |
|
50 |
|
|
5 |
250 |
240 |
02932 |
|
75 |
|
|
7 |
350 |
340 |
02933 |
|
100 |
|
|
8 |
400 |
380 |
02934 |
I |
25 |
25 |
25 |
3,5 |
150 |
140 |
02935 |
|
50 |
|
|
4,5 |
300 |
280 |
02936 |
|
75 |
|
|
6 |
350 |
340 |
02937 |
|
100 |
|
|
7 |
450 |
420 |
02938 |
|
125 |
|
|
8,5 |
500 |
470 |
02939 |
I |
50 |
30 |
30 |
4 |
300 |
290 |
02940 |
|
75 |
|
|
5 |
400 |
390 |
02941 |
|
100 |
|
|
6 |
450 |
440 |
02942 |
|
150 |
|
|
8,5 |
550 |
540 |
02943 |
|
200 |
|
|
11,5 |
650 |
640 |
02944 |
|
300 |
|
|
15,5 |
800 |
790 |
02945 |
I |
100 |
40 |
40 |
7,3 |
500 |
480 |
02946 |
|
150 |
|
|
7,6 |
600 |
590 |
02947 |
|
200 |
|
|
9,5 |
700 |
680 |
02948 |
|
250 |
|
|
11 |
800 |
780 |
02949 |
|
300 |
|
|
13 |
900 |
850 |
02950 |
|
400 |
|
|
15,5 |
1000 |
980 |
02951 |
II |
140 |
50 |
50 |
6 |
650 |
630 |
Typ II

|
02952 |
|
210 |
|
|
8 |
800 |
780 |
02953 |
|
280 |
|
|
10 |
950 |
900 |
02954 |
|
420 |
|
|
14 |
1050 |
1000 |
02955 |
|
560 |
|
|
16 |
1350 |
1200 |
02956 |
II |
140 |
60 |
60 |
6,5 |
700 |
680 |
02957 |
|
210 |
|
|
8 |
900 |
850 |
02958 |
|
350 |
|
|
11 |
1150 |
1100 |
02959 |
|
490 |
|
|
13 |
1350 |
1300 |
02960 |
|
560 |
|
|
15 |
1400 |
1350 |
02961 |
III |
340 |
80 |
80 |
9,5 |
1200 |
1100 |
Typ III

|
02962 |
|
500 |
|
|
11,5 |
1500 |
1400 |
02963 |
|
670 |
|
|
14,5 |
1700 |
1600 |
02964 |
|
840 |
|
|
16 |
1900 |
1800 |
02965 |
|
1000 |
|
|
19,5 |
2100 |
1950 |
02966 |
III |
500 |
100 |
100 |
11 |
1600 |
1500 |
02967 |
|
670 |
|
|
12,5 |
1850 |
1790 |
02968 |
|
840 |
|
|
14,5 |
2100 |
2000 |
02969 |
|
1000 |
|
|
17,5 |
2250 |
2150 |
02970 |
|
1200 |
|
|
19 |
2450 |
2350 |
02971 |
|
1500 |
|
|
23,5 |
2700 |
2550 |
02972 |
III |
600 |
120 |
120 |
12 |
1900 |
1750 |
02973 |
|
1000 |
|
|
16 |
2650 |
2500 |
02974 |
|
1500 |
|
|
21 |
3400 |
3200 |
02975 |
|
2000 |
|
|
26 |
3950 |
3800 |
02976 |
|
3000 |
|
|
36 |
4800 |
4550 |
02977 |
|
4500 |
|
|
51 |
5400 |
5400 |
|
Note: The defined load capacities are independent
standard values for non-insulated versions. The reduction factor
for insulated versions depending on the application is between
15-20 %. The standard version is non-insulated. Standard
insulation is PVC. If desired we can provide materials such as
silicone fibre-glass shrinking plastic tubing etc. If required
please indicate: Part No. Overall length; if drill holes are
required then please include the type or provide a schematic; if
insulation is desired then please indicate specifications. For
insulation other than PVC please indicate which type and if they
should be impermeable to liquid then please indicate this as well. |
|
|