Article Groups
Service
|
Ready assembled cables manufactured in druseidt press-technology |
TPE-U insulated high current cables 300/500 V resp. 450/750 V
Technical data
Construction and application
For high current applications and to connect electrical devices we
offer our TPE-U insulated cables for a voltage range 300/500 V or
450/750 V. The electrical conductor consists out of a round stranded
copper cable with a wire-Ø of 0,3 mm which is insulated with a special
TPE-U compound. The insulating material is free of halogen. It enables a
flexible and simple installation also of longer cables distances in a
short time. The use of ready assembled cables, manufactured in druseidt
crimp-technology, in length and with contact areas in coordination with
the application offer a further possibility to reduce the installation
time to a minimum. The cables are well suited to connect transformers,
generators or rectifiers inside of industrial plants as well as electroplating
equipments. Caused by the big conductor cross-sections up to 500 mm²
they offer an alternative to busbar systems. Additionally to the cable we
offer suitable cable lugs, crimping- and cutting-tools. So it is
possible to buy a complete mounting system by our company. Standard
colour for the 300/500 V design is orange and for the 450/750 V design
green. Other colours like black, red, blue etc. and minimum quantities
on request.
Technical data
Conductor
- round stranded copper cable made out of annealed Cu-ETP1 wires
acc. to DIN EN 13602
- surface uncoated
- wire-Ø 0,3 mm
Insulation material
- TPE-U, free of halogen
- orange colour (300/500 V design)
- green colour (450/750 V design)
- operating voltage U0/U
Part-No. 15202-15214 300/500 V
Part-No. 15216-15228 450/750 V
- testing voltage
Part-No. 15202-15214 3,4 kV
Part-No. 15216-15228 4,0 kV
- operating temperature
fixed -50° C up to +90° C
moved -40° C up to +70° C
Delivery
- in rings or on wooden drums
|
|
Part-No.
|
technical data |
cross-section
mm2 |
dimensions mm |
current load
dep. to conductor heat |
diameter and no. of wires |
outer-Ø |
insulation thickness ca. |
70° C |
80° C |
|
15202 |
120 |
1698 |
x |
0,30 |
18,7 |
1,6 |
380 A |
420 A |
15204 |
150 |
2166 |
x |
0,30 |
20,9 |
1,8 |
440 A |
480 A |
15206 |
185 |
2622 |
x |
0,30 |
23,0 |
2,0 |
500 A |
550 A |
15208 |
240 |
3400 |
x |
0,30 |
26,5 |
2,0 |
590 A |
650 A |
15210 |
300 |
4275 |
x |
0,30 |
29,5 |
2,0 |
675 A |
740 A |
15212 |
400 |
5660 |
x |
0,30 |
33,0 |
2,0 |
810 A |
890 A |
15214 |
500 |
7076 |
x |
0,30 |
37,5 |
2,0 |
925 A |
1020 A |
|
15216 |
120 |
1698 |
x |
0,30 |
18,9 |
1,7 |
380 A |
420 A |
15218 |
150 |
2166 |
x |
0,30 |
21,1 |
1,9 |
440 A |
480 A |
15220 |
185 |
2622 |
x |
0,30 |
23,2 |
2,1 |
500 A |
550 A |
15222 |
240 |
3400 |
x |
0,30 |
27,5 |
2,5 |
590 A |
650 A |
15224 |
300 |
4275 |
x |
0,30 |
30,5 |
2,5 |
675 A |
740 A |
15226 |
400 |
5660 |
x |
0,30 |
34,0 |
2,5 |
810 A |
890 A |
15228 |
500 |
7076 |
x |
0,30 |
38,5 |
2,5 |
925 A |
1020 A |
|
Remark: All information about current load are approximate values in
consideration of the cables heat for single laying of air cooled cables and
ambient temperature +30° C. The temperature of the conductor is in dependent
of the installation, the application, the cooling, the ambient temperature
etc., so that if necessary reducing factors are to be considered. |
|